Austin Flush Door

WATER PROOF PLYWOOD

Austin Flush Door's are made of seasoned plywood's which are water - borer - termite proof. They are an ideal choice for homes, offices and bedrooms. Special treatments are done for weather proofing, this will also help increasing the product durability. Austin Plywood is the best water proof plywood in India.

single_project
  • 100% High Quality Meghalayan Pine Wood.
  • 500 % Lifetime warranty.
  • Boiling Water Proof.
  • E1 Emission Level.
  • Quadruple Pressed. ( Two times Pre-pressing and two times Hot Pressing).
  • Double Calibrated for uniform thickness.
  • 3-Tier Preservative Treatment : Pressure impregnation treated fillers, GLP and Full Cell ACC ( Acid copper Chrome).
  • Bonded with un extended phenol Formaldehyde Resin of BWP Grade.
  • Strictly follow Pre-pressing Technique. Pre-Pressing ensures sufficient time for transferring of wood preservative in each and every particles of veneer before Hot Pressing. It helps in distribution of moistureand adhesive more uniformly to make the plywood more strong , durable and free from warping, twisting and cupping.

TECHNICAL SPECIFICATIONS

  • Dimension and Tolerance
    • Length, mm : +2mm, 0mm
    • Width, mm : +2mm, 0mm
    • Thickness, % : +0.5%
    • Variation in Thickness, mm : 0.25
    • Squareness, % : 0.15mm
    • Edge Straigntness, % : 0.09%
  • General Flatness Test : 1.2mm
  • Local Planeness Test : 0.18mm
  • Impact Indentation Test
    • Shall have no defects such as cracking, tearing or delamination : No cracking, tearing or delamination observed
    • The depth of indentation shall not be more than 0.2 mm : 0.05mm
  • Edge Loading Test
    • The deflection of the edge at the maximum load shall not be more than 5 mm. : 2.15mm
    • The residual deflection shall not be more than 0.5 mm. : 0.19mm
    • Lateral buckling shall not be more than 2 mm : 0.35mm
    • No residual buckling after removal of load. : No residual buckling after removal of load
  • Shock Resistance
    • Shall be no visible damage in any part of the door after twenty five blows on each end. : No visible damage observed.
    • No significant permanent deformation and without deterioration after five impact on both sides of the shutter. : No significant permanent deformation or deterioration observed.
  • Buckling Test
    • The initial deflection shall not be more than 50 mm : 18mm
    • The residual deflection shall not be more than 5 mm : 1.95mm
  • Misuse Test
    • Shall not be any permanent of the fixing or any part of the door set in hindering its normal working after the test : No permanent deformation in any part of the door observed
  • Slamming Test
    • Shall not have any visible damage in any part of the door after 50 successive impacts : No visible damage observed
  • Varying Test
    • There shall not be any visible warping, twisting or delamination : No visible warping, twisting or delamination observed
    • The maximum departure from the general planeness shall not be more than 1.0 mm : 0.35mm
    • The recovery of the original size after subjecting the door to high and low humidity shall be at least 90 percent of the change in dimension : 97%
  • End Immersion Test
    • Shall have no delamination at the end of the test : No delamination observed
  • Knife Test
    • Minimum pass Standard : Excellent
  • Glue Adhesion Test
    • Shall be considered to have pass the test if no delamination has occurred in the glue lines. : No delamination observed
    • No single delamination of more than 50 mm in length and 3 mm in depth in the glue lines between plywood faces and stiles and rails : No delamination observed
  • Screw withdrawal Test
    • The required load to withdraw the screw completely shall not be less than 1000 N : 1525 N
    • On withdrawal, there shall be no visible damage to the surface either by delamination or extra chipping off at the points of withdrawal : No visible damage or chipping off observed.